Network Time Server 7001(RC) with NTP LAN Board(s) 7273(RC) or 7274(RC)

Short Description

By implementation of NTP LAN Boards 7273(RC) or NTP LAN Boards 7274(RC) (10/100/1000 Mbit/s autosensing, VLAN, Bonding, PRP) system 7001(RC) becomes a highly accurate NTP Stratum 1 Time Server for synchronization of computers and industrial networks.

System 7001(RC) can either be delivered with NTP LAN Board(s) 7273(RC) / with NTP LAN Board(s) 7274(RC) from the factory or subsequently extended by board(s) 7273(RC) / 7274(RC) in the field.

  • System 7001: up to 8 NTP LAN Board(s) 7273 / 7274 implementable
  • System 7001RC: up to 31 NTP LAN Board(s) 7273RC / 7274RC implementable

The modular design structure of system 7001(RC) also allows the combination of one board 7273(RC) / one board 7274(RC) with any other function board suitable for system 7001(RC).

Features

GPS version

  • GPS System to be modularly equipped with function boards
  • High availability based on hot-plug capability:
    • Removal and installation of function boards during operation
    • Failure of single function boards do not influence the functions of the other boards
  • Channels for parameterization/monitoring:
    • Keypad and operating menu via display
    • Serial connection via the hmc (hopf Management Console)
    • WEB-GUI and SNMP for function boards with LAN interface
    • Option: LAN connection via the hmc including monitoring via SNMP
  • Subsequent extension by additional function boards
  • Error-Management to be parameterised
  • Potential isolation of the GPS antenna circuit
  • Synchronisation with just one satellite possible
  • SyncOFF Timer (bridging of reception failure) providing an error-free operation even under difficult reception conditions
  • Redundant multiple test mechanism of the synchronisation signal providing a correct and leap-free signal evaluation
  • High free running accuracy
  • Maintenance-free back-up clock for three days
  • System completely maintenance-free
  • Options:
    • Power supplies for various operating voltages
    • Multi source functionality:
      Synchronisation via an additional signal input with automatic switch-over between GPS and the second synchronization source
    • Supply in 6U (6U/84HP) or 9U (9U/84HP) rack for implementation of more function boards and/or more extensions slots
    • Redundant power supplies
    • OCXO crystal basis for increased free running accuracy
    • Status LEDs in the front panel
    • Extension by a Switch-Box (System 5000) for automatic switch-over of signals between two systems (Master Clock and redundant Master Clock)
  • Specific hardware and software customizations

DCF77 version

  • DCF77 System to be modularly equipped with function boards
  • High availability based on hot-plug capability:
    • Removal and installation of function boards during operation
    • Failure of single function boards do not influence the functions of the other boards
  • Channels for parameterization/monitoring:
    • Keypad and operating menu via display
    • Serial connection via the hmc (hopf Management Console)
    • WEB-GUI and SNMP for function boards with LAN interface
    • Option: LAN connection via the hmc including monitoring via SNMP
  • Subsequent extension by additional function boards
  • Error-Management to be parameterised
  • Potential isolation of the DCF77 antenna circuit
  • SyncOFF Timer (bridging of reception failure) providing an error-free operation even under difficult reception conditions
  • Redundant multiple test mechanism of the synchronisation signal providing a correct and leap-free signal evaluation
  • High free running accuracy
  • Maintenance-free back-up clock for three days
  • System completely maintenance-free
  • Options:
    • Power supplies for various operating voltages
    • Multi source functionality:
      Synchronisation via an additional signal input with automatic switch-over between DCF77 and the second synchronization source
    • Supply in 6U (6U/84HP) or 9U (9U/84HP) rack for implementation of more function boards and/or more extensions slots
    • Redundant power supplies
    • OCXO crystal basis for increased free running accuracy
    • Status LEDs in the front panel
    • Extension by a Switch-Box (System 5000) for automatic switch-over of signals between two systems (Master Clock and redundant Master Clock)
  • Specific hardware and software customizations

Features of NTP/SINEC H1 LAN Board 7273(RC)

  • Alarming
    • SNMPv2c / SNMPv3 (MIB II, hopf Private Enterprise MIB, SNMP traps)
    • E-Mail Notification
    • SYSLOG
  • Routing for configuring static routes based on special network configuration requirements
  • SINEC H1 time datagram

Features of NTP/SINEC H1 LAN Board 7274(RC)

  • all features of NTP/SINEC H1 LAN Board 7273(RC)
  • 2 ethernet interfaces 10/100/1000 Mbit/s autosensing
  • Activation options:
    • VLAN support according to IEEE 802.1q
    • Port aggregation (NIC Bonding/Teaming) with support of IEEE 802.3ad trunks
    • Parallel Redundancy Protocol (PRP) according to IEC 62439-3
    • Precision Time Protocol (PTP) according to IEC 1588

Erweiterungen

The base system 7001(RC)-DCF is equipped with function boards for the output of required signals according to the provided customer specifications. The possible number of functions boards to be integrated and upgraded is primarily determined by the number of available slots in 19" rack and the power supply capacity.

Please note:

  • Board number _ _ _ _ RC: only available for system 7001RC
  • Board number _ _ _ _ (RC): available for system 7001 as well as system 7001RC
  • Board number _ _ _ _ : only available for system 7001

Function Boards for System Bus

Function Boards

Synchronisation Boards and Modules

Management Boards

Pictures

System 7001RC System 7001RC System 7001RC System 7001RC

Downloads

PDF documents

Software and Driver